HCS04.2E-W0590驱动器修理:
F218 Heatsink Overtemperature Shutdown散热器过热停机
Description:说明:
The temperature of the DKC heatsink will be monitored.将监测DKC散热器的温度。
If the temperature of the heatsink is too high, the drive will power down in order to protect against damage.
如果散热器温度过高,驱动器将断电以防止损坏。
Cause:原因:
1. Ambient temperature is too high.
环境温度过高。
The specified operational data is valid up to an ambient temperature of 45°C.指定的操作数据在环境温度不超过45°C时有效。
2. The DKC's heatsink is dirty.
DKC的散热器脏了。
3. Air flow is prevented by other assembly parts or a control cabinet panel assembly.气流由其他组件零件或控制柜面板组件阻止。
4. Heatsink blower may be defective
散热器鼓风机可能存在故障
Remedy:
1. Reduce the ambient temperature; for example, through cooling
of the control cabinet
降低环境温度;例如,通过冷却控制柜的
2. Remove any obstruction or dirt from the heatsink.
清除散热器上的任何障碍物或污垢。
3. Install the device vertically and clear a large enough area for
proper heatsink ventilation.
垂直安装设备,并清理足够大的区域适当的散热器通风。
4. Exchange drive.
更换驱动器