BAUMULLER包米勒控制器维修:116Timeout of I2C Bus Read/Write EepromI2C总线读/写Eeprom超时.
驱动器报警116怎么维修:
A timeout error occurred in the I2C Bus. I2C总线中发生超时错误。
The serial I2C EEPROM is connected to the DSP via the I2C Bus.
串行I2C EEPROM通过I2C总线连接到DSP。
Effect: 效果:
The Board ID and production data are stored in the I2C EEPROM.
板ID和生产数据存储在I2C EEPROM中。
The error may lead to an incorrect board configuration.
该错误可能导致板配置不正确。
1019Undervoltage DC link voltage欠压直流链路电压
Error Undervoltage DC link voltage is detected through the FPGA.
错误通过FPGA检测欠压直流链路电压。
Setting the error bit in the FPGA and activating the error message
only occurs when the pulses are activated.
在FPGA中设置错误位并激活错误消息仅在脉冲被激活时发生。
The pulses will then be blocked in the FPGA.
然后,这些脉冲将在FPGA中被阻断。
Therefore, the only permitted response is the pulse block.
因此,唯一允许的响应是脉冲块。