力士乐DKS01.1-W050A-DL01-01-FW维修:F218 Heatsink Overtemperature Shutdown散热器过热停机。
Description:说明:The temperature of the DKC heatsink will be monitored. If the temperature of the heatsink is too high, the drive will power down in order to protect against damage.将监测DKC散热器的温度。如果散热器温度过高,驱动器将按顺序断电以防止损坏。
力士乐伺服放大器线路板维修:Cause:
1. Ambient temperature is too high. The specifiedoperational data is valid up to an ambient temperature of 45°C.
环境温度过高。指定的操作数据在45°C的环境温度下有效。
2. The DKC's heatsink is dirty.
DKC的散热器脏了。
3. Air flow is prevented by other assembly parts or a control cabinet panel assembly.
气流由其他组件零件或控制柜面板组件阻止。
4. Heatsink blower may be defective
散热器鼓风机可能存在故障
Remedy:
1. Reduce the ambient temperature; for example, through cooling of the control cabinet
降低环境温度;例如,通过冷却控制柜
2. Remove any obstruction or dirt from the heatsink.
清除散热器上的任何障碍物或污垢。
3. Install the device vertically and clear a large enough area for proper heatsink ventilation.
垂直安装设备,并清理足够大的区域,以便进行适当的散热器通风。
4. Exchange drive.
交换驱动器。
转载请注明出处:上海仰光电子科技专业伺服驱动器维修,伺服电机维修
本文链接:http://www.shygdz.com/fuwu/Services_Show19858.htm
伺服驱动器维修 伺服电机维修 触摸屏维修 变频器维修
电话:021-50157782
手机:13817011982 微信同号
邮箱:shygdzi@163.com
联系人:张工
网址:http://www.shygdz.com
【 我们确保修好测试好给客户!!!!】
下一篇:没有了