黄浦倍福伺服驱动器维修:F73F, Feedback "general": Feedback id has been incorrectly parametrized反馈“常规”:反馈id参数设置错误。
The internal ID parametrized in the feedback system does not correspond to the ID entered in the IDN "P-0-0150" or "P-0-0180".反馈系统中参数化的内部ID与IDN“P-0-0150”或“P-0-0180”中输入的ID不一致。
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
诊断代码(十六进制)诊断代码(Dez)
F73F 63295
Class Type
类别类型
Error Parameter error
参数错误
Standard Reaction Reset
标准反应复位
The power stage is already switched off Execute Reset-Command (S-0-0099).
电源级已关闭执行复位命令(S-0-0099)。
Possible Causes Solutions
可能的原因解决方案
You have selected an incorrect feedback system. Compare the selected feedback system with the actually existing one.
您选择的反馈系统不正确。将选定的反馈系统与实际存在的反馈系统进行比较。
The feedback database was incorrectly parametrized. Call our support dept. and replace the feedback database.
反馈数据库的参数设置不正确。致电我们的支持部门并更换反馈数据库。
During the motor replacement a motor with different feedback was connected.
在更换电机期间,连接了一个具有不同反馈的电机。
Please correct the feedback-parameterization.
请更正反馈参数化。
Further Information AX5000_IDN-Description: "P-0-0150-->Parameter channel-->Identifier" or "P-0-0180-->Parameter channel-->Identifier。进一步信息AX5000_IDN-说明:“P-0-0150-->参数通道-->标识符”或“P-0-0180-->参数通道->标识符。